HEAT EXCHANGER DESIGN | 92% 1-Stage | 95% 1-Stage | 95% Hi. Eff. | 95% 2-Stage |
Aluminized steel design primary heat exchanger with crimped no weld construction | a | a | a | a |
AL 29-4C stainless steel secondary heat exchanger | a | a | a | a |
Non-welded, crimped S-curve primary heat exchanger design for maximum durability |
|
|
| a |
FURNACES
BURNER(S) | 92% 1-Stage | 95% 1-Stage | 95% Hi. Eff. | 95% 2-Stage |
Aluminized steel inshot burners for smooth ignition | a | a | a | a |
Isolated burner enclosure for quiet operation |
|
|
| a |
CABINET CONSTRUCTION | 92% 1-Stage | 95% 1-Stage | 95% Hi. Eff. | 95% 2-Stage |
Compact 33” height | a | a | a | a |
Standardized widths for easy coil fit | a | a | a | a |
Unitized construction for cabinet integrity |
|
|
| a |
Heat exchanger compartment is insulated to increase efficiency and reduce sound levels |
|
|
| a |
Baked on pre-painted steel cabinet finish |
|
|
| a |
AIR DELIVERY SYSTEM | 92% 1-Stage | 95% 1-Stage | 95% Hi. Eff. | 95% 2-Stage |
Multi-speed PSC blower motor | a | a |
|
|
Easily removable slide-out blower design | a | a | a | a |
Multi-speed high efficiency (constant torque) blower motor |
|
| a |
|
Enhanced cooling SEER ratings when applied with properly matched cooling equipment |
|
| a |
|
Efficient ECM variable speed blower motor |
|
|
| a |
Motor features “soft start” and “soft stop” for quiet operation |
|
|
| a |
Active and passive dehumidification feature |
|
|
| a |
Dynamically balanced blower wheel with resilient motor mounts for smooth and quiet operation |
|
|
| a |
CONTROLS | 92% 1-Stage | 95% 1-Stage | 95% Hi. Eff. | 95% 2-Stage |
Single stage gas valve | a | a | a |
|
Self diagnostics saves last 5 fault codes regardless of power interruption | a | a |
|
|
Self diagnostics saves last 10 fault codes regardless of power interruption |
|
| a |
|
Control features electronic air cleaner and humidifier terminals | a | a | a |
|
Durable silicon nitride ignitor |
|
| a |
|
Two stage gas valve |
|
|
| a |
Integrated ignition and fan control |
|
|
| a |
System sentry control retains last five fault codes with push button memory recall, regardless of power interruption |
|
|
| a |
Hot surface ignition system uses silicon nitride ignitor |
|
|
| a |
Control features 120 volt electric air cleaner and humidifier terminals |
|
|
| a |
Control circuit is fuse protected |
|
|
| a |
Colour coded control wiring |
|
|
| a |
Compatible with single or two stage thermostats for heating |
|
|
| a |
VENTING | 92% 1-Stage | 95% 1-Stage | 95% Hi. Eff. | 95% 2-Stage |
Designed certified for direct and non-direct applications | a | a | a | a |
Easily vented with PVC pipe |
|
| a |
|
2-speed induced draft motor with stainless steel shaft, steel ball bearings, and fan cooled for long life |
|
|
| a |
Vent materials for Canadian applications must comply with ULCS636 |
|
|
| a |
INSTALLATION FEATURES | 92% 1-Stage | 95% 1-Stage | 95% Hi. Eff. | 95% 2-Stage |
Left or right utility connection | a | a | a | a |
Zero step horizontal conversion | a | a | a | a |
Removable floor base for bottom return air | a | a | a | a |
Photos and information copyright Concord Air.